0.6/1kV Cu or Al /XLPE/PVC Insulated Power Cables
0.6/1kV Cu or Al /XLPE/PVC Insulated Power Cables
0.6/1kV Cu or Al /XLPE/PVC Insulated Power Cables
0.6/1kV Cu or Al /XLPE/PVC Insulated Power Cables
+
  • 0.6/1kV Cu or Al /XLPE/PVC Insulated Power Cables
  • 0.6/1kV Cu or Al /XLPE/PVC Insulated Power Cables
  • 0.6/1kV Cu or Al /XLPE/PVC Insulated Power Cables
  • 0.6/1kV Cu or Al /XLPE/PVC Insulated Power Cables

0.6/1kV Cu or Al /XLPE/PVC Insulated Power Cables

XLPE insulated power cables for rated voltages of 1 kV (Um = 1,2 kV) is used to transmit power on the power transmission and distribution line of A.C.50Hz, rated voltage 1kV or below. They are specifically suitable for use in industrial applications, particularly underground installations, where additional mechanical protection is required. These cables can be securely installed on cable trays, within conduits, or fixed to walls.

CE

Categories:

Low Voltage Cables

Introduction
XLPE insulated power cables for rated voltages of 1 kV (Um = 1,2 kV) is used to transmit power on the power transmission and distribution line of A.C.50Hz, rated voltage 1kV or below. They are specifically suitable for use in industrial applications, particularly underground installations, where additional mechanical protection is required. These cables can be securely installed on cable trays, within conduits, or fixed to walls.


Instruction of Application
Rated Voltage: 0.6/1kV
Conductor
Class 1 solid copper/aluminum  conductor
Class 2 stranded circular or circular compacted
Insulation
XLPE (Cross-Linked Polyethylene)
Outer Sheath
PVC (Polyvinyl Chloride)

The Main Technical Parameter Of The Cable
1)Cable conductor DC resistance: See the table 1-1
2)AC voltage test: See the table 1-2
3)Allowed continuous current capacity of unarmoured cable: See the table1-3
4)Allowed continuous current capacity of armoured cable: See the table 1-4


Table 1-1 Max. DC resistance of cable conductor at 200°C

Rated cross area(mm2)

0.5

0.75

1.0

1.5

2.5

4

6

10

Cu(Ω/km)

Non tinned  

36.0

24.5

18.1

12.1

7.41

4.61

3.08

1.83

Tinned

36.7

24.8

18.2

12.2

7.56

4.70

3.11

1.84

Al (Ω/km)

/

/

/

18.1

12.1

7.41

4.61

3.08

Rated cross area(mm2)

16

25

35

50

70

95

120

150

Cu (Ω/km)

Non tinned

1.15

0.727

0.524

0.387

0.268

0.193

0.153

0.124

Tinned

1.16

0.734

0.529

0.391

0.270

0.195

0.154

0.126

Al (Ω/km)

1.91

1.20

0.868

0.641

0.443

0.320

0.253

0.206

Rated cross area(mm2)

185

240

300

400

500

630

800

1000

Cu  (Ω/km)

Non tinned  

0.0991

0.0754

0.0601

0.0470

0.0366

0.0283

0.0221

0.0176

Tinned

0.100

0.0762

0.0607

0.0475

0.0369

0.0286

0.0224

0.0177

Al ( Ω/km)

0.164

0.125

0.100

0.0778

0.0605

0.0469

0.0367

0.0291

 

 Table 1-2 AC voltage test of cable

Rated Voltage kV  

0.6/1

Test Voltage kV

3.5

Test Time min

5

 

Table 1-3 Allowed continuous current capacity of unarmoured cable
Conditions:Environment temperature:400C;
Soil temperature:250C;
Soil thermal receptivity: 2000C·cm/W

 

Nominal Area of Conductor

Allowed continuous current capacity in air(A)

Allowed continuous current capacity in soil(A)

Copper cable

Aluminum cable

Copper cable

Aluminum cable

Singlecore

Multi core

Singlecore

Multi core

Singlecore

Multi core

Singlecore

Multi core

2.5

34

32

27

25

36

32

27

25

4

44

41

35

32

47

41

35

32

6

56

52

45

42

59

52

46

42

10

77

70

60

53

78

69

59

53

16

100

91

78

70

102

90

77

71

25

132

118

102

91

130

117

104

91

35

164

150

127

114

169

143

117

113

50

196

182

 152

146

187

169

139

134

70

251

228

195

178

226

208

174

165

95

305

273

236

214

269

247

208

195

120

351

314

272

246

300

282

239

221

150

401

360

311

278

339

321

269

247

185

461

410

359

319

382

356

300

278

240

546

483

424

378

435

408

348

321

300

611

552

474

419

495

469

391

365

400

716

/

546

/

574

/

456

/

 

 The depth underground: 0.8m
Table 1-4 Allowed continuous current capacity of armoured cable
Conditions:Environment temperature:400C;
Soil temperature:250C;
Soil thermal receptivity: 2000C·cm/W

Nominal Area of Conductor

mm2

Allowed continuous current capacity in air(A)

Allowed continuous current capacity in soil(A)

Copper core cable

Aluminum core cable

Copper core cable

Aluminum core cable

Multi core

Multi core

Multi core

Multi core

4

41

32

41

32

6

52

42

52

42

10

70

53

69

53

16

91

70

90

71

25

118

91

117

91

35

150

114

143

113

50

182

146

169

134

70

228

178

208

165

95

273

214

247

195

120

314

246

282

221

150

360

278

321

247

185

410

319

356

278

240

483

378

408

321

300

552

419

469

365

 

Key words:

Insulated Power Cable

Get A Quote

Leave your contact information and get a free product quote

Project Cases

Zhengzhou Zoom Link Cable Co., Ltd. is a high-tech, high-growth, internationalized enterprise with an integrated production plant, integrating R&D, production and sales.

Related Products

Zhengzhou Zoom Link Cable Co., Ltd. is a high-tech, high-growth, internationalized enterprise with an integrated production plant, integrating R&D, production and sales.

Online Message

Leave your contact information and get a free product quote

SUBMIT

ONE LAST STEP

Please fill in your relevant information, we will ensure that we can provide professional services

SUBMIT